EKI-1242OUMS

EKI-1242IOUMS-AEKI-1242OUMS-A

MODBUS TO FIELDBUS GATEWAY

EKI-1242OUMS - Modbus TCP/RTU to OPC UA Fieldbus Gateway with 4x 10/100 Ethernet and 2x RS-232/422/485 serial ports

CE

CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.

RoHS

This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.

Wide Voltage

These devices and systems have been designed to accept a wide voltage DC power input. This feature is desirable in the industrial market where a fixed voltage level or mains AC power cannot be guaranteed.

DIN-rail mountable

These devices have been designed to be mounted directly on to an industry standard DIN-rail.

FCC Approved

The Federal Communications Commission (FCC) is an independent agency of the United States government that sets standards and governs the testing of conducted and radiated emissions such as EMI.

Wide Temperature

These products utilise high quality industrial grade components enabling them to work in wide temperature environments. They are capable of running as low as -20C and as high as +70C.

Extended Wide Temperature

These products utilise high quality industrial grade components enabling them to work in extended wide temperature environments. They are capable of running below -20C and above +70C and offer further protection than standard wide temperature rated products.

5 Year Warranty

These products come with a standard five year manufacturer warranty.

EKI-1242OUMS Modbus to Fieldbus Gateway
EKI-1242OUMS
From
£471
Free delivery to UK mainland addresses

Add to cart / quote list

Buy the EKI-1242OUMS online or add it to your quote list to send to our sales team for a quote on all your chosen products
Product
Availability
Price
EKI-1242IOUMS-A

EKI-1242OUMS with extended operating temperature (-40°C to +75°C)

1-4
£471
FREE DELIVERYBUY
EKI-1242OUMS-A

EKI-1242OUMS with wide operating temperature (-10°C to +60°C)


This product is now end of life. Please contact us however, as we may be able to source small quantities or arrange OEM quantity production runs with the factory if required. Impulse can also assist you in upgrading your requirement to a new long-term platform.
All prices exclude VAT at current rate.
Minimum order value - £30 (exc. VAT and delivery).
Free delivery of the EKI-1242OUMS to UK Mainland on orders over £150 (exc. VAT and delivery) when purchasing online - excludes Northern Ireland, Isle of Man, Isle of Wight, Scottish Islands and the Channel Islands.

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)
Industry insight.
Network know-how.
Impulse engineers and specialists have the industry insight and network know-how to design forward looking solutions for wide-ranging environments.
Discover our Industrial IoT capabilities

EKI-1242OUMS overview

Features
Description
Downloads
  • Designed for protocol extensibility and adaption
  • Seamless integration between Modbus RTU/TCP and OPC UA communication
  • 4x 10/100Mbps RJ45 Ethernet ports
  • 2x RS-232/422/485 software selectable DB9 serial ports
  • Modbus TCP Master mode supports 64 connections
  • Supports OPC UA server with up to 128 connections
  • Mountable via DIN-rail and wall-mount
  • Supports 12V to 48V DC dual power input for power redundancy
  • Extended operating temperature 'I' model available (-40°C to +75°C)
The EKI-1242OUMS industrial protocol gateway not only provides seamless communication between Fieldbus and industrial Ethernet but also supports different protocol devices. The EKI-1242OUMS can integrate new and existing Modbus RTU/TCP devices on to OPC UA networks.

The EKI-1242OUMS is an uncomplicated and cost-effective way to efficiently transfer I/O data between devices.

For more information about the EKI-1242OUMS industrial Fieldbus gateway please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry.
 
Enquire about the EKI-1242OUMS
Need more info or project pricing for the EKI-1242OUMS?
T: +44 (0)1782 337 800 • E: sales@impulse-embedded.co.uk

Similar products to the EKI-1242OUMS

EKI-1242ECMS
EtherCAT Fieldbus Gateway
  • Protocol: EtherCAT, Modbus RTU, Modbus T...
  • No. of LAN ports: 4
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended
EKI-1242EIMS
Modbus Ethernet IP Gateway
  • Protocol: Ethernet/IP, Modbus RTU, Modbu...
  • No. of LAN ports: 4
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended
EKI-1242PNMS
Modbus to Profinet Gateway
  • Protocol: Modbus RTU, Modbus TCP, PROFIN...
  • No. of LAN ports: 4
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended
EKI-1242BNMS
BACnet IP Gateway
  • Protocol: BACnet, Modbus RTU, Modbus TCP
  • No. of LAN ports: 5
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended
MGate 5118
EtherNet IP Gateway
  • Protocol: CAN-J1939, Ethernet/IP, Modbus...
  • No. of LAN ports: 2
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended, Standar...
MGate 5111
Modbus PROFINET to PROFIBUS Gateway
  • Protocol: Ethernet/IP, Modbus RTU, Modbu...
  • No. of LAN ports: 2
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended, Standar...
MGate 5103
Modbus to PROFINET Gateway
  • Protocol: Ethernet/IP, Modbus RTU, Modbu...
  • No. of LAN ports: 2
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended, Standar...
MGate 5217
Modbus BACnet IP Gateway
  • Protocol: BACnet, Modbus RTU, Modbus TCP
  • No. of LAN ports: 2
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended
MGate 5101-PBM-MN
PROFIBUS to Modbus Gateway
  • Protocol: Modbus TCP, PROFIBUS
  • No. of LAN ports: 1
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended, Standar...
MGate 4101-MB-PBS
Modbus to PROFIBUS Gateway
  • Protocol: Modbus RTU, PROFIBUS
  • Serial interface: RS-232/422/485
  • Operating temperature: Extended, Standar...
  • No. of LAN ports: None
+44(0)1782 337 800
WE'RE HIRING!If you are looking for a new and exciting challenge please take a look at our recruitment page
C-Tecnics
The support received from Impulse on new solutions is greatly appreciated and highly recommended.
...
Sep 2021
+44(0)1782 337 800