Impulse Embedded is a leading provider of Industrial computing systems and solutions. Our customers rely on us to provide the best embedded computing products and solutions for the challenges presented by today’s industrial demands. Together with our global manufacturing partners we provide world-class innovative embedded computing and automation products and solutions suitable for multiple industrial market sectors.

Not found what you're looking for?

We're only a phone call away. Contact us for more information or for personalised help with your project.

Contact Us

The MGate 5118 series industrial protocol gateways support the SAE J1939 protocol, which is based on CANBus (Controller Area Network). SAE J1939 is used to implement communication and diagnostics among vehicle components, diesel engine generators, and compression engines, and is suitable for the heavy duty truck industry and backup power systems.

It is now common to use an engine control unit (ECU) to control these kinds of devices, and more and more applications are using PLCs for process automation to monitor the status of J1939 devices connected behind the ECU.

The MGate 5118 series gateways support the Modbus RTU/ASCII/ TCP, EtherNet/IP, and PROFINET protocols to support most PLC applications. Devices that support the J1939 protocol can be monitored and controlled by PLCs and SCADA systems that use the Modbus RTU/ASCII/TCP, EtherNet/IP, and PROFINET protocols. With the MGate 5118, you can use the same gateway in a variety of PLC environments.

For more information about the MGate 5118 gateway please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry.

Features
  • Protocol conversion between J1939 and Modbus/PROFINET/EtherNet/IP
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Supports J1939 protocol
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • microSD card for configuration backup/duplication and event logs
  • Status monitoring and fault protection for easy maintenance
  • CAN bus and serial port with 2 kV isolation protection
  • -40°C to +75°C wide operating temperature models available
  • Security features based on IEC 62443
Baud Rate 50 bps to 921.6 kbps
Communication Interface Ethernet
Device Type Converts J1939 to Modbus, PROFINET, or EtherNet/IP
Ethernet Ports 2
Ethernet Speed 10/100BaseT(x)
Input Voltage 12 to 48 VDC
Market Certifications CE, FCC,ATEX, Class I Division 2, IECEx
Mounting DIN-Rail
Operating Temperature 0 to 60°C, -40 to 75°C (-T model)
Protocol Support Modbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO Device, EtherNet/IP Scanner, EtherNet/IP Adapter
Warranty 5 Years

Delivery & Returns

We offer a range of delivery options to suit your needs.

UK Mainland

  • Free next day shipping on all orders over £150 (UK Mainland only)
  • Next day delivery - £12 (UK Mainland only)
  • Postcode Exclusions: ZE, KW15+ PO 30, JE, HS, GY, TR, IM, AB31+, KW 1-14, FK19+, PA20+, IV, PH

Northern Ireland & Highlands

  • Northern Ireland (2 business day delivery) - from £40 (UKIMS required for NI)
  • Highlands delivery (up to 3 business days) - from £30

Ireland

  • Ireland Economy (2-5 business days) - from £35
  • Ireland Priority (1-3 business days) - from £50

RMA

In order to process returned goods, Impulse Embedded Limited uses an internal RMA system. Before returning goods for any reason, please contact Impulse Embedded Limited (returns@impulse-embedded.co.uk) to request an RMA number. Please confirm the reason for the return of the goods, providing the Serial Number, Product Code, and Impulse Embedded Limited Invoice Number (if known).

When returning goods, please ensure they are suitably packed so as to avoid damage, are in the original packaging, along with all accessories, with the outer packaging marked with the RMA number. It is recommended that you use a signed delivery service, as goods lost in transit are not the responsibility of Impulse Embedded Limited.

Please do not write the RMA number on the goods or on the original packaging. Impulse Embedded Limited may refuse returned goods and return them if they arrive without an RMA number, or not in the original packaging.

Moxa 1 Port Can-J1939 to Modbus/Profinet/EtherNet/IP Gateway

Please complete the details below to receive your quote

Select the products of this series that you wish to request quantity or project pricing, or lead time information for:

  • MGATE 5118-T

    1 Port Can-J1939 to Modbus/Profinet/EtherNet/IP Gateway – Extended Wide Operating Temperature

  • MGATE 5118

    1 Port Can-J1939 to Modbus/Profinet/EtherNet/IP Gateway

Add to List