ICF-1180I

PROFIBUS TO FIBRE CONVERTER

Moxa Fieldbus   •  Fieldbus
ICF-1180I profibus to fibre converter
ICF-1180IICF-1180I
ICF-1180I - 1 Port Industrial PROFIBUS to Fibre Converter
CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.
This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.
Underwriters Laboratories (UL) is an independent product safety certification organisation based in the United States. UL develops standards for products, materials, components, assemblies, tool and equipment, mainly dealing with product safety.
The National Electrical Code (NEC) defines hazardous environments as areas “where fire or explosion hazards may exist due to flammable gases, vapours, liquids, dust or particles”. When such materials are found in the atmosphere of an area, a potential for explosion exists, which could be ignited if an electrical or other source of ignition is present. As defined by the classification authorities, certified devices are suitable for installation and operation within a Class 1, Division 2 environment. Class 1 environments are areas where there is a presence of flammable gases or vapours in the air, such as natural gas or petroleum vapour. Facilities including oil rigs, refineries, gas plants and automotive repair centres all fall within this category.
These devices and systems have been designed to accept a wide voltage DC power input. This feature is desirable in the industrial market where a fixed voltage level or mains AC power cannot be guaranteed.
These devices have been designed to be mounted directly on to an industry standard DIN-rail.
The Federal Communications Commission (FCC) is an independent agency of the United States government that sets standards and governs the testing of conducted and radiated emissions such as EMI.
These products utilise high quality industrial grade components enabling them to work in extended wide temperature environments. They are capable of running below -20C and above +70C and offer further protection than standard wide temperature rated products.
These products come with a standard five year manufacturer warranty.
ATEX is the name commonly given to the European Directive 94/9/EC, also known as ATEX 95 or ATEX Equipment Directive. The regulation applies to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems. There are two categories of equipment 'I' for mining and 'II' for surface industries. The directive covers a large range of equipment, potentially including electrical equipment used on fixed offshore platforms, in petrochemical plants, mines, flour mills and other areas where a potentially explosive atmosphere may be present.
Certified to standards relating to equipment for use in applications subject to explosive atmospheres.
4 ICF-1180I versions available
From
£319

Add to cart / quote list

Buy the ICF-1180I online or add it to your quote list to send to our sales team for a quote on all your chosen products
Version filter
Operating temperature
Version information
Lead time*
1 off price**
Request qty / trade pricing**
Buy now
ICF-1180I-M-ST
ICF-1180I with multi-mode ST port (0°C to +60°C)
£319
ICF-1180I-S-ST
ICF-1180I with single-mode ST port (0°C to +60°C)
£550
ICF-1180I-M-ST-T
ICF-1180I with multi-mode ST port (-40°C to +75°C)
£363
ICF-1180I-S-ST-T
ICF-1180I with single-mode ST port (-40°C to +75°C)
£596
All prices exclude VAT at current rate.
Minimum order value - £50 (exc. VAT and delivery).
Free delivery of the ICF-1180I to UK Mainland on orders over £150 (exc. VAT and delivery) when purchasing online - excludes Northern Ireland, Isle of Man, Isle of Wight, Scottish Islands and the Channel Islands.

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)

ICF-1180I overview

  • Fibre cable test function validates fibre communication
  • Auto baudrate detection and data speed up to 12Mbps
  • PROFIBUS bus fail prevents corrupted datagram in functioning segment
  • Fibre inverse feature
  • Alarm by relay output
  • 2kV galvanic isolation protection
  • Extends PROFIBUS transmission distance up to 45km
  • Supports Fibre Signal Intensity Diagnosis
  • Dual power inputs for redundancy (Reverse power protection)
  • 12V to 48V DC power input
  •  -40°C to +75°C operating temperature (on -T version)
The ICF-1180I series of industrial PROFIBUS-to-fibre converters are used to convert PROFIBUS signals from copper to optical fibre. The converters are used to extend serial transmission up to 4km (multi-mode fibre) or up to 45km (single-mode fibre).

The ICF-1180I provides 2kV isolation protection for the PROFIBUS system and dual power inputs to ensure that your PROFIBUS device will perform uninterrupted.

Fibre-optic cables are usually deployed for long distance communication. To ensure proper communication across the fibre-optic cables, engineers use fibre sensors. With fibre cable test function through DIP switch adjustments, the ICF-1180I series converters eliminate the need to rely on fibre-optic sensors.

This function not only detects fibre communication abnormalities but also validates the format of the received packet. It can also determine which side (Tx or Rx) is causing the problem.

For more information about the ICF-1180I media converter please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry.
Need a helping hand?
Our networking FAEs are trained to the highest level, so not only do we sell products but we can show you how to configure and troubleshoot using best practice. If you want to know more give us a try.
Ask us a question
OPC-UA
OPC-UA is supported by many of our communication and I/O products. If you are interested but not quite sure how to implement OPC-UA into your factory then get in touch.
Enquire now
Network configuration support
Do you need some help to pre-configure your switches, maybe you need help setting up security or using network management software. Tell us what you need and we will gladly help.
Enquire now

Related products

Customers who bought the ICF-1180I also bought these items
Enquire about the ICF-1180I
Need more info or project pricing for the ICF-1180I?
T: +44 (0)1782 337 800 • E: SALES@IMPULSE-EMBEDDED.CO.UK
We want you to be the first to know about new products, technology solutions and exclusive industry news. To stay connected and receive marketing communications, select YES. (Remember, you are free to unsubscribe at any time.)

 
LIVE CHAT OFFLINE (OPEN UK 8:30AM-5:00PM MON - FRI)
Your Favourites
Wherever you see this heart symbol around the site, you can click to add things like products, articles and more to your favourites.
Build a quote list
Are you after more than one product, or need quantity pricing? Add products to your quote list and send it through to our team in one go!