Impulse Embedded is a leading provider of Industrial computing systems and solutions. Our customers rely on us to provide the best embedded computing products and solutions for the challenges presented by today’s industrial demands. Together with our global manufacturing partners we provide world-class innovative embedded computing and automation products and solutions suitable for multiple industrial market sectors.
Not found what you're looking for?
We're only a phone call away. Contact us for more information or for personalised help with your project.
The MGate MB3170 from Moxa is an advanced Modbus gateway with 1 port that converts between Modbus TCP, ASCII, and RTU communication protocols. Providing serial to ethernet communication as a serial (master) to serial (slave). Additionally, there is support for simultaneous connection of serial and Ethernet masters with serial Modbus devices. The MGate MB3170 gateway supports daisy-chaining multiple gateways via its dual Ethernet ports, all models are din rail mountable so not needing an extra switch will make cabling quick, clean and easy. Dual power DC inputs offer an extra layer of reliability for demanding industrial applications. A priority control function can ensure defined urgent commands get an immediate response in larger complex Modbus networks where lag becomes a concern. The MGate MB3170 gateway can be accessed by up to 16x TCP master/clients or connect to up to 32x TCP slave/servers. Routing through the serial ports can be controlled by IP address, TCP port number, or ID mapping. A featured priority control function allows urgent commands to obtain an immediate response. A relay output is provided for the Ethernet link and power input status. The relay output gives maintenance engineers an additional tool for troubleshooting and maintenance. For more information about the MGate MB3170 Ethernet Modbus gateway please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry
Delivery & Returns
We offer a range of delivery options to suit your needs.
UK Mainland
Northern Ireland & Highlands
Ireland
RMA
In order to process returned goods, Impulse Embedded Limited uses an internal RMA system. Before returning goods for any reason, please contact Impulse Embedded Limited (returns@impulse-embedded.co.uk) to request an RMA number. Please confirm the reason for the return of the goods, providing the Serial Number, Product Code, and Impulse Embedded Limited Invoice Number (if known).
When returning goods, please ensure they are suitably packed so as to avoid damage, are in the original packaging, along with all accessories, with the outer packaging marked with the RMA number. It is recommended that you use a signed delivery service, as goods lost in transit are not the responsibility of Impulse Embedded Limited.
Please do not write the RMA number on the goods or on the original packaging. Impulse Embedded Limited may refuse returned goods and return them if they arrive without an RMA number, or not in the original packaging.
Moxa 1 Port RS-232/422/485 Ethernet Modbus Gateway Wide Temperature Operation
Please complete the details below to receive your quote
Select the products of this series that you wish to request quantity or project pricing, or lead time information for:
MGATE MB3170I-M-SC-T
1 Port Isolated RS-232/422/485 Ethernet Modbus Gateway Multi-Mode SC Fibre Extended Wide Temperature Operation
MGATE MB3170I-M-SC
1 Port Isolated RS-232/422/485 Ethernet Modbus Gateway Multi-Mode SC Fibre,
MGATE MB3170-M-ST
1 Port RS-232/422/485 Ethernet Modbus Gateway Multi-Mode ST Fibre Wide Temperature Operation
MGATE MB3170-M-ST-T
1 Port RS-232/422/485 Ethernet Modbus Gateway Multi-Mode ST Fibre Extended Wide Temperature Operation
MGATE MB3170I-S-SC-T
1 Port Isolated RS-232/422/485 Ethernet Modbus Gateway Single-Mode SC Fibre Extended Wide Temperature Operation
MGATE MB3170I-S-SC
1 Port Isolated RS-232/422/485 Ethernet Modbus Gateway Single-Mode SC Fibre Wide Temperature Operation
MGATE MB3170-M-SC
1 Port RS-232/422/485 Ethernet Modbus Gateway Multi-Mode SC Fibre Wide Temperature Operation
MGATE MB3170-S-SC-T
1 Port RS-232/422/485 Ethernet Modbus Gateway Single-Mode SC Fibre Extended Wide Temperature Operation
MGATE MB3170
1 Port RS-232/422/485 Ethernet Modbus Gateway Wide Temperature Operation
MGATE MB3170-M-SC-T
1 Port RS-232/422/485 Ethernet Modbus Gateway Multi-Mode SC Fibre Extended Wide Temperature Operation
MGATE MB3170-S-SC
1 Port RS-232/422/485 Ethernet Modbus Gateway Single-Mode SC Fibre Wide Temperature Operation
MGATE MB3170I
1 Port Isolated RS-232/422/485 Ethernet Modbus Gateway Wide Temperature Operation
Spurious error messages, especially those from rolling-stock subsystems, can be difficult and time consuming to diagnose. Siemens Rail, in Manchester, wished to install a data logging system onto their rolling stock to transmit data in real-time back to their depot for efficient data analysis by their team.