Advantech 4 Port Modbus TCP/RTU to OPC UA Fieldbus Gateway – 4x 10/100 Ethernet – 2x RS-232/422/485 Ports

EKI-1242IOUMS-A
extended operating temperature (-40°C to +75°C)

Who We Are

Impulse Embedded is a leading provider of Industrial computing systems and solutions. Our customers rely on us to provide the best embedded computing products and solutions for the challenges presented by today’s industrial demands. Together with our global manufacturing partners we provide world-class innovative embedded computing and automation products and solutions suitable for multiple industrial market sectors.

Not found what you're looking for?

We're only a phone call away. Contact us for more information or for personalised help with your project.

Contact Us

The EKI-1242OUMS industrial protocol gateway not only provides seamless communication between Fieldbus and industrial Ethernet but also supports different protocol devices. The EKI-1242OUMS can integrate new and existing Modbus RTU/TCP devices on to OPC UA networks.

The EKI-1242OUMS is an uncomplicated and cost-effective way to efficiently transfer I/O data between devices.

For more information about the EKI-1242OUMS industrial Fieldbus gateway please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry.
 

Features
  • Ethernet Communication :
  • Ports : 2 x RJ45 Ethernet Ports
  • Compatibility : IEEE 802.3, IEEE 802.3u
  • Speed : 10/100Mbps, Auto MDI/MDIX
  • Protection : 1.5KV Magnetic Isolation
  • Serial Communication :
  • Serial Ports : 1 x RS-232/422/485 DB9 Port, Software Selectable
  • Data Bits : 7, 8
  • Stop Bits : 1, 2
  • Parity : None, Odd, Even, Space, Mark
  • Flow Control : XON/XOFF, RTS/CTS, DTR/DSR
  • Baud Rate : 50bps to 921.6kbps, Any Baud Rate Setting
  • Serial Signals : See Datasheet
  • Protection : 15KV ESD For All Signals
  • For Software and Protocol Support, See Datasheet
  • Mechanical :
  • Dimensions : W34mm x H140mm x D95mm
  • Enclosure : Metal with Solid Mounting Hardware
  • Mounting : DIN-rail, Wall-mount
  • Weight : 0.592Kg
  • Power :
  • Power Input : 12V to 48V DC, Redundant Dual Input
  • Power Consumption : 2W
  • Environmental :
  • Operating Temperature : -10°C to +60°C
  • Storage Temperature : -20°C to +80°C
  • Operating Humidity : 5% to 95% Relative Humidity
  • MTBF : 227,175 Hours
  • Certification :
  • EMC : CE, FCC Part 15 Subpart B (Class A)
  • Safety : UL/cUL 60950-1
  • Hazardous : Class 1 Division 2
  • Designed for protocol extensibility and adaption
  • Seamless integration between Modbus RTU/TCP and OPC UA communication
  • 4x 10/100Mbps RJ45 Ethernet ports
  • 2x RS-232/422/485 software selectable DB9 serial ports
  • Modbus TCP Master mode supports 64 connections
  • Supports OPC UA server with up to 128 connections
  • Mountable via DIN-rail and wall-mount
  • Supports 12V to 48V DC dual power input for power redundancy
  • Extended operating temperature 'I' model available (-40°C to +75°C)
Baud Rate 50 bps to 921.6 kbps
Communication Interface Ethernet
Device Type Modbus TCP/RTU to OPC UA Fieldbus Gateway
Ethernet Ports 4
Ethernet Speed 10/100BaseT(x)
Input Voltage 12 ~ 48 VDC, redundant dual inputs
Market Certifications CE, FCC Part 15 Subpart B (Class A)
Mounting DIN-rail, Wall
Operating Temperature -40 ~ 75 °C
Protocol Support Modbus RTU/TCP (Client), UPC UA (Server)
There are no downloads currently available.

Delivery & Returns

We offer a range of delivery options to suit your needs.

UK Mainland

  • Free next day shipping on all orders over £150 (UK Mainland only)
  • Next day delivery - £12 (UK Mainland only)
  • Postcode Exclusions: ZE, KW15+ PO 30, JE, HS, GY, TR, IM, AB31+, KW 1-14, FK19+, PA20+, IV, PH

Northern Ireland & Highlands

  • Northern Ireland (2 business day delivery) - from £40 (UKIMS required for NI)
  • Highlands delivery (up to 3 business days) - from £30

Ireland

  • Ireland Economy (2-5 business days) - from £35
  • Ireland Priority (1-3 business days) - from £50

RMA

In order to process returned goods, Impulse Embedded Limited uses an internal RMA system. Before returning goods for any reason, please contact Impulse Embedded Limited (returns@impulse-embedded.co.uk) to request an RMA number. Please confirm the reason for the return of the goods, providing the Serial Number, Product Code, and Impulse Embedded Limited Invoice Number (if known).

When returning goods, please ensure they are suitably packed so as to avoid damage, are in the original packaging, along with all accessories, with the outer packaging marked with the RMA number. It is recommended that you use a signed delivery service, as goods lost in transit are not the responsibility of Impulse Embedded Limited.

Please do not write the RMA number on the goods or on the original packaging. Impulse Embedded Limited may refuse returned goods and return them if they arrive without an RMA number, or not in the original packaging.

Advantech 4 Port Modbus TCP/RTU to OPC UA Fieldbus Gateway – 4x 10/100 Ethernet – 2x RS-232/422/485 Ports

Please complete the details below to receive your quote

Select the quantity you wish to request pricing or lead time information for:

  • EKI-1242IOUMS-A

    4 Port Modbus TCP/RTU to OPC UA Fieldbus Gateway – 4x 10/100 Ethernet – 2x RS-232/422/485 Ports

Add to List