DSCA38

STRAIN GAUGE INPUT MODULE

DSCA38 - Strain Gauge Input DIN Module, 3kHz Bandwidth

CE

CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.

RoHS

This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.

UL

Underwriters Laboratories (UL) is an independent product safety certification organisation based in the United States. UL develops standards for products, materials, components, assemblies, tool and equipment, mainly dealing with product safety.

Class 1 Division 2 Certified

The National Electrical Code (NEC) defines hazardous environments as areas “where fire or explosion hazards may exist due to flammable gases, vapours, liquids, dust or particles”. When such materials are found in the atmosphere of an area, a potential for explosion exists, which could be ignited if an electrical or other source of ignition is present. As defined by the classification authorities, certified devices are suitable for installation and operation within a Class 1, Division 2 environment. Class 1 environments are areas where there is a presence of flammable gases or vapours in the air, such as natural gas or petroleum vapour. Facilities including oil rigs, refineries, gas plants and automotive repair centres all fall within this category.

DIN-rail mountable

These devices have been designed to be mounted directly on to an industry standard DIN-rail.

ATEX approved

ATEX is the name commonly given to the European Directive 94/9/EC, also known as ATEX 95 or ATEX Equipment Directive. The regulation applies to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems. There are two categories of equipment 'I' for mining and 'II' for surface industries. The directive covers a large range of equipment, potentially including electrical equipment used on fixed offshore platforms, in petrochemical plants, mines, flour mills and other areas where a potentially explosive atmosphere may be present.

DSCA38 Strain Gauge Input Module
Featured in:Dataforth Signal Conditioning Modules

Request a quote for this product

Enquiry information  
Your name  
Company name  
Email address  
Telephone  

Add to quote list

Add the DSCA38 to your quote list to send to our sales team for a quote on all your chosen products
Product
Availability
DSCA38-01

DSCA38 with Full Bridge, 3mV/V sensitivity, -10mV to +10mV input, -10V to +10V output

DSCA38-02

DSCA38 with Full Bridge, 3mV/V sensitivity, -30mV to +30mV input, -10V to +10V output

DSCA38-03

DSCA38 with Half Bridge, 3mV/V sensitivity, -10mV to +10mV input, -10V to +10V output

DSCA38-04

DSCA38 with Half Bridge, 3mV/V sensitivity, -30mV to +30mV input, -10V to +10V output

DSCA38-05

DSCA38 with Full Bridge, 2mV/V sensitivity, -20mV to +20mV input, -10V to +10V output

DSCA38-06

DSCA38 with Full Bridge, 10mV/V sensitivity, -33.3mV to +33.3mV input, -10V to +10V output

DSCA38-07

DSCA38 with Full Bridge, 10mV/V sensitivity, -100mV to +100mV input, -10V to +10V output

DSCA38-08

DSCA38 with Full Bridge, 3mV/V sensitivity, -10mV to +10mV input, 0 to +10V output

DSCA38-08C

DSCA38 with Full Bridge, 3mV/V sensitivity, -10mV to +10mV input, 4mA to 20mA output

DSCA38-08E

DSCA38 with Full Bridge, 3mV/V sensitivity, -10mV to +10mV input, 0 to 20mA output

DSCA38-09

DSCA38 with Full Bridge, 3mV/V sensitivity, -30mV to +30mV input, 0 to +10V output

DSCA38-09C

DSCA38 with Full Bridge, 3mV/V sensitivity, -30mV to +30mV input, 4mA to 20mA output

DSCA38-09E

DSCA38 with Full Bridge, 3mV/V sensitivity, -30mV to +30mV input, 0 to 20mA output

DSCA38-10

DSCA38 with Half Bridge, 3mV/V sensitivity, -10mV to +10mV input, 0 to +10V output

DSCA38-10C

DSCA38 with Half Bridge, 3mV/V sensitivity, -10mV to +10mV input, 4mA to 20mA output

DSCA38-10E

DSCA38 with Half Bridge, 3mV/V sensitivity, -10mV to +10mV input, 0 to 20mA output

DSCA38-11

DSCA38 with Half Bridge, 3mV/V sensitivity, -30mV to +30mV input, 0 to +10V output

DSCA38-11C

DSCA38 with Half Bridge, 3mV/V sensitivity, -30mV to +30mV input, 4mA to 20mA output

DSCA38-11E

DSCA38 with Half Bridge, 3mV/V sensitivity, -30mV to +30mV input, 0 to 20mA output

DSCA38-12

DSCA38 with Full Bridge, 2mV/V sensitivity, -20mV to +20mV input, 0 to +10V output

DSCA38-12C

DSCA38 with Full Bridge, 2mV/V sensitivity, -20mV to +20mV input, 4mA to 20mA output

DSCA38-12E

DSCA38 with Full Bridge, 2mV/V sensitivity, -20mV to +20mV input, 0 to 20mA output

DSCA38-13

DSCA38 with Full Bridge, 10mV/V sensitivity, -33.3mV to +33.3mV input, 0 to +10V output

DSCA38-13C

DSCA38 with Full Bridge, 10mV/V sensitivity, -33.3mV to +33.3mV input, 4mA to 20mA output

DSCA38-13E

DSCA38 with Full Bridge, 10mV/V sensitivity, -33.3mV to +33.3V input, 0 to 20mA output

DSCA38-14

DSCA38 with Full Bridge, 10mV/V sensitivity, -100mV to +100mV input, 0 to +10V output

DSCA38-14C

DSCA38 with Full Bridge, 10mV/V sensitivity, -100mV to +100mV input, 4mA to 20mA output

DSCA38-14E

DSCA38 with Full Bridge, 10mV/V sensitivity, -100mV to +100mV input, 0 to 20mA output

DSCA38-15

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +10mV input, 0 to +10V output

DSCA38-15C

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +10mV input, 4mA to 20mA output

DSCA38-15E

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +10mV input, 0 to 20mA output

DSCA38-16

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +30mV input, 0 to +10V output

DSCA38-16C

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +30mV input, 4mA to 20mA output

DSCA38-16E

DSCA38 with Full Bridge, 3mV/V sensitivity, 0 to +30mV input, 0 to 20mA output

DSCA38-17

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +10mV input, 0 to +10V output

DSCA38-17C

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +10mV input, 4mA to 20mA output

DSCA38-17E

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +10mV input, 0 to 20mA output

DSCA38-18

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +30mV input, 0 to +10V output

DSCA38-18C

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +30mV input, 4mA to 20mA output

DSCA38-18E

DSCA38 with Half Bridge, 3mV/V sensitivity, 0 to +30mV input, 0 to 20mA output

DSCA38-19

DSCA38 with Full Bridge, 2mV/V sensitivity, 0 to +20mV input, 0 to +10V output

DSCA38-19C

DSCA38 with Full Bridge, 2mV/V sensitivity, 0 to +20mV input, 4mA to 20mA output

DSCA38-19E

DSCA38 with Full Bridge, 2mV/V sensitivity, 0 to +20mV input, 0 to 20mA output

DSCA38-20

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +33.3mV input, 0 to +10V output

DSCA38-20C

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +33.3mV input, 4mA to 20mA output

DSCA38-20E

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +33.3mV input, 0 to 20mA output

DSCA38-21

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +100mV input, 0 to +10V output

DSCA38-21C

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +100mV input, 4mA to 20mA output

DSCA38-21E

DSCA38 with Full Bridge, 10mV/V sensitivity, 0 to +100mV input, 0 to 20mA output

Product
Availability
PWR-PS5R7W

DIN Rail Switching Power Supplies with 7.5W 24V DC power

SCMXRAIL1-02

EN50022-35 Gull Wing DIN Rail, Length 2M

SCMXRAIL2-02

EN50035-G32 G Style DIN Rail, Length 2M

SCMXRAIL3-02

EN50022-35x15 Gull Wing DIN Rail, Length 2M

PWR-PS5R15W

DIN Rail Switching Power Supplies with 15W 24V DC power

PWR-PS5R30W

DIN Rail Switching Power Supplies with 30W 24V DC power

PWR-PS5R60W

DIN Rail Switching Power Supplies with 60W 24V DC power

PWR-PS5R120W

DIN Rail Switching Power Supplies with 120W 24V DC power

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)
Industry insight.
Network know-how.
Impulse engineers and specialists have the industry insight and network know-how to design forward looking solutions for wide-ranging environments.
Discover our Industrial IoT capabilities

DSCA38 overview

Description
Downloads

Each DSCA38 strain gauge input module provides a single channel of strain gage input which is filtered, isolated, amplified, and converted to a high level voltage output. Signal filtering is accomplished with a five-pole filter which is optimized for step response.

An anti-aliasing pole is located on the field side of the isolation barrier, and the other four poles are on the system side. After the initial field-side filtering, the input signal is chopped by a proprietary chopper circuit. Isolation is provided by transformer coupling, again using a proprietary technique to suppress transmission of common mode spikes or surges.

Features
  • Interfaces to 100? through 10K? Strain Gages
  • 10kHz Signal Bandwidth
  • Industry Standard Output of either ±10V, 0-20mA, or 4-20mA
  • 1500Vrms Transformer Isolation
  • ANSI/IEEE C37.90.1 Transient Protection
  • Input Protected to 240VAC Continuous
  • True 3-Way Isolation
  • Wide Range of Supply Voltage
  • 100dB CMR
  • Fully Isolated Excitation Supply
  • ±0.03% Accuracy
  • ±0.01% Linearity
  • Easily Mounts on Standard DIN Rail
  • C-UL-US Listed
  • CE and ATEX Compliant
Enquire about the DSCA38
Need more info or project pricing for the DSCA38?
T: +44 (0)1782 337 800 • E: sales@impulse-embedded.co.uk
 
 
 
 

Similar products to the DSCA38

+44(0)1782 337 800
+44(0)1782 337 800