ioLogik 2542

ANALOG DIGITAL IO MODULE

Moxa IOLogik Remote I/O Shop  •  Analog Distributed IO  •  Ethernet
ioLogik 2542 Analog Digital IO Module
ioLogik 2542ioLogik 2542Click&Go Plus
ioLogik 2542 - Smart Ethernet Remote 4 Channel Isolated Analog Input/12 Digital I/O Module with Click&Go Plus
CE is a mandatory standard for products on the market in the European Economic Area. By CE marking a product, the manufacturer ensures that the item meets the essential safety requirements set out in the applicable CE directive.
This product fully adheres to the Restriction of Hazardous Substances Directive 2002/95/EC, RoHS for short.  The directive covers the restriction of use of certain hazardous substances in electrical and electronic equipment and was adopted in February 2003 by the European Union.
Underwriters Laboratories (UL) is an independent product safety certification organisation based in the United States. UL develops standards for products, materials, components, assemblies, tool and equipment, mainly dealing with product safety.
The National Electrical Code (NEC) defines hazardous environments as areas “where fire or explosion hazards may exist due to flammable gases, vapours, liquids, dust or particles”. When such materials are found in the atmosphere of an area, a potential for explosion exists, which could be ignited if an electrical or other source of ignition is present. As defined by the classification authorities, certified devices are suitable for installation and operation within a Class 1, Division 2 environment. Class 1 environments are areas where there is a presence of flammable gases or vapours in the air, such as natural gas or petroleum vapour. Facilities including oil rigs, refineries, gas plants and automotive repair centres all fall within this category.
These devices and systems have been designed to accept a wide voltage DC power input. This feature is desirable in the industrial market where a fixed voltage level or mains AC power cannot be guaranteed.
These devices have been designed to be mounted directly on to an industry standard DIN-rail.
The Federal Communications Commission (FCC) is an independent agency of the United States government that sets standards and governs the testing of conducted and radiated emissions such as EMI.
These products utilise high quality industrial grade components enabling them to work in extended wide temperature environments. They are capable of running below -20C and above +70C and offer further protection than standard wide temperature rated products.
These products come with a standard five year manufacturer warranty.
ATEX is the name commonly given to the European Directive 94/9/EC, also known as ATEX 95 or ATEX Equipment Directive. The regulation applies to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems. There are two categories of equipment 'I' for mining and 'II' for surface industries. The directive covers a large range of equipment, potentially including electrical equipment used on fixed offshore platforms, in petrochemical plants, mines, flour mills and other areas where a potentially explosive atmosphere may be present.
2 ioLogik 2542 versions available
From
£423

Add to cart / quote list

Buy the ioLogik 2542 online or add it to your quote list to send to our sales team for a quote on all your chosen products
Version information
Lead time*
1 off price**
Request qty / trade pricing**
Buy now
ioLogik 2542
ioLogik 2542 with wide operating temperature (-10°C to +60°C)
£423
ioLogik 2542-T
ioLogik 2542 with extended operating temperature (-40°C to +75°C)
£497
Peripheral information
Lead time*
1 off price**
Request qty / trade pricing**
Buy now
All prices exclude VAT at current rate.
Minimum order value - £50 (exc. VAT and delivery).
Free delivery of the ioLogik 2542 to UK Mainland on orders over £150 (exc. VAT and delivery) when purchasing online - excludes Northern Ireland, Isle of Man, Isle of Wight, Scottish Islands and the Channel Islands.

* Lead time is indicative and is subject to change at time of ordering. Next business day delivery on in-stock products only (when ordered before 3pm).
** Contact us for quantity or project pricing.
† Additional delivery charge may be incurred for certain postcodes (calculated at checkout)

ioLogik 2542 overview

  • Front-end intelligence with Click&Go Plus control logic, up to 48x rules
  • Active communication with MX-AOPC UA Server
  • Automatically complement disconnection period data with MX-AOPC UA Logger software
  • 4-port unmanaged switch built in for linking to Ethernet devices
  • I/O expansion port for daisy chaining up to 8x ioLogik E1200 units
  • 3-in-1 RS-232/422/485 serial port for connecting to serial devices in the field
  • Supports SNMPv1/v2c/v3
  • Simplify I/O management with MXIO library for Windows or Linux platforms
  • 9V to 48V DC
  • -30°C to +70°C operating temperature (on -T version)
The ioLogik 2500 is a smart remote I/O product with unique hardware and software designs, making it an ideal solution for a variety of industrial data acquisition applications. The ioLogik 2500’s hardware design includes a 4-port unmanaged Ethernet switch and 2x serial ports, enabling the ioLogik 2500 to seamlessly connect to a variety of field devices.

One of the Ethernet ports can be used to link to 8x daisy-chained ioLogik E1200 expansion modules to provide more than 100 channels. The ioLogik 2500 acts as the “head” unit, with Click&Go Plus logic used to control the entire I/O array. Most importantly, the ioLogik 2500’s single IP is all that’s required to connect the entire I/O array to your network, providing the perfect solution for industrial field sites that have an insufficient number of IP addresses.

The new Click&Go Plus control logic now supports up to 48x rules with further upgrades to 8x onditions/actions. In addition, its graphical user interface provides 3x logic gates and 3x multi-layers, helping you build more powerful and efficient IO solutions. Once you finish setting up your Click&Go Plus logic rules, IOxpress’s easy-to-use simulation function can be used to find potential errors in your Click&Go Plus rules before uploading them to your online devices. Peer-to-peer (P2P) mode is widely used for industrial applications.

Traditionally, you would need to use P2P devices on both sides of the connection. However, if a configuration mismatch occurred between the P2P devices, the P2P connection would fail, after which you would need to spend extra time and effort to check the P2P settings. With IOxpress, all you need to do is set up the output device, and the P2P connection will be established automatically.

The ioLogik 2500’s unique IO expansion hardware design lets you link up to 8x ioLogik E1200 modules into a versatile I/O array with 100+ different I/O channels. The ioLogik 2500 acts as the perfect “head” unit, using Click&Go Plus logic to control the entire I/O array, and providing a single IP to connect the entire I/O array to your network.

IOxpress integrates a user-friendly interface with offline/online configuration, allowing you to configure every I/O parameter offline, and then upload the settings to your online devices, greatly reducing the time and cost needed to manage and configure your IO solutions.

The ioLogik 2500 supports micro SD cards with up to 32GB of memory, turning the ioLogik into a powerful datalogger for storing valuable data. And with a built-in FTP server, important data from field sites can be accessed remotely by different systems. In addition, the 2x serial communication ports can be used to input data from devices using the Modbus RTU protocol, and then transform the data into Modbus TCP or AOPC tag format before sending it out over the Ethernet network.

The new MX-AOPC UA supports both UA server and DA server types. MX-AOPC UA server has a number of strengths. UA server provides a standard, state of the art security model, assuring your system’s security, and supports communication channels via the standard UA TCP port. This means that messages can be relayed through third party proxies. In addition, configuring the firewall is be easier, since you won’t need to worry about DCOM settings.

In addition, MX-AOPC supports both the traditional Modbus protocol and Moxa’s patented Push type communication. Unlike the traditional passive “pull” method, “active” messages are automatically “pushed” from the ioLogik 2500 to the SCADA system when the I/O state changes or pre-configured events occur.

For more information about the ioLogik 2542 please contact our technical sales team on +44 (0)1782 337 800 or alternatively submit an enquiry.
OPC-UA
OPC-UA is supported by many of our communication and I/O products. If you are interested but not quite sure how to implement OPC-UA into your factory then get in touch.
Ask us a question
Enquire about the ioLogik 2542
Need more info or project pricing for the ioLogik 2542?
T: +44 (0)1782 337 800 • E: SALES@IMPULSE-EMBEDDED.CO.UK
We want you to be the first to know about new products, technology solutions and exclusive industry news. To stay connected and receive marketing communications, select YES. (Remember, you are free to unsubscribe at any time.)

 
LIVE CHAT OFFLINE (OPEN UK 8:30AM-5:00PM MON - FRI)
Your Favourites
Wherever you see this heart symbol around the site, you can click to add things like products, articles and more to your favourites.
Build a quote list
Are you after more than one product, or need quantity pricing? Add products to your quote list and send it through to our team in one go!